Digital H.D.T. Heat Deflection Tester

QC-656A
Digital H.D.T. Heat Deflection Tester

Send us an Inquiry

Description

The specimen is given a flexion stress at the center, and the temperature should increase by 2 degrees Celsius per minute. When the specimen’s center undergoes a deflection of 0.254mm, the temperature is determined as the specimen’s deflection temperature.
The tester is equipped with touch screen that guides users step by step. A user-friendly interface and standardized process are designed to orientate users in the shortest possible and to reduce test errors. The system has built-in calculation function, user can enter the specimen dimension to get the required weight. During the process, the specimen holder and the weight frame automatically rise and descend to facilitate specimen’s installment. This tester has 6 test stations, each one can show the independent temperature and displacement on the display. When it reaches deflection value, it will record the temperature and stops and start cooling system. Smart testing process is time-saving and requires only a minimum of testers.

Conform to Standards

  • ASTM D648
  • ISO 75-1

Industry

Plastic

Specifications


Model

QC-656A

Temperature

Room temperature - 300℃

Temperature Control

2℃ increase per minute (adjustable)

Weight

Weight support 2.7 N.
Each station has the following weights: 0.1N×1, 0.2N×2, 0.5N×1, 1N×1, 2N×2, 5N×1, 10N×1

Deflection Reading

0.001~3.000 mm

Flexion Span

100 mm, 64mm (101.6mm for options)

Specimen Support’s Surface

R=3.0 mm (able to add the Vicat heat deflection test head)

Stations

6 test stations

Oil Chamber Capacity

25 L

Dimension

48 x 110 x 125 cm

Weight

230 kg (Empty); 250 kg (oil inlcuded)

Power

Single Phase 220VAC

Accessories

Weights

Standard accessories include weights 0.1N×1、0.2N×2、0.5N×1、1N×1、2N×2、5N×1、10N×1